Sign In | Join Free | My himfr.com |
|
Ask Lasest Price | |
Brand Name : | GDZX |
Model Number : | ZX267X Series |
Certification : | ISO |
Price : | USD$500.00-2000/sets |
Payment Terms : | L/C, T/T, Western Union, D/P |
Supply Ability : | 1000sets/ month |
Delivery Time : | 5-10 work days |
Product Introduction:
This series of products is a basic type voltage withstanding tester
with excellent performance. The output voltage is regulated by
regulator of high reliability and high durability. LED digital high
brightness screen displaying test time, voltage, current, real-time
displaying breakdown current value and voltage value; alarm current
value freely preset; test time display in three digital tube, the
minimum resolution time 0.1s, time preset range 0.0s to 999s.
Equipped with the signal input and output interface for PLC, it can
be easily integrated with PLC for a test system, quickly and
accurately measure the dielectric strength of electronic
components, household appliances, insulation materials, instruments
and meters, lighting appliances and electric heating appliances.
Reference Standards:
This series of products meet the following standards:
Household appliances standards(IEC60335, GB4706-1-2001, GB4706-1-1998)
lighting standards(IEC60598-1-1999, GB7000-1-2000)
Information standards(GB8898-2001, GB12113, GB4943-2001, IEC60065, IEC60950)
Medical standards ( IEC601-1-1998, GB4706.1-1998, GB4793.1-2007 ) etc.
Model series :
AC | DC | |||||
5KV | 10KV | 20KV | 5KV | 10KV | 20KV | |
ZX2670A | 20mA | -- | -- | -- | -- | -- |
ZX2671A | -- | 20mA | -- | -- | 10mA | -- |
ZX2671B | -- | 50mA | -- | -- | 20mA | -- |
ZX2671C | -- | 100mA | -- | -- | 20mA | -- |
ZX2672A | 20mA | -- | -- | 10mA | -- | -- |
ZX2672B | 100mA | -- | -- | -- | -- | -- |
Technical Parameter:
1) Technical parameter of ZX2670A,ZX2672A,ZX2672B,ZX2672C,ZX2672D
Items | Model | ZX2670A | ZX2672A | ZX2672B | ZX2672C | ZX2672D | |
ACW | Output voltage range | (0.00~5.00)kV | |||||
Maximum output power | 100VA (5.000kV/20mA) | 500VA (5.0kV/100mA) | 1000VA (5.0kV/200mA) | ||||
Maximum rated current | 20mA | 100mA | 200mA | ||||
Current stalls | 2mA,20mA | 2mA,20mA,100mA | 2mA,20mA,200mA | ||||
Output waveform | Sine wave | ||||||
Output waveform distortion | ≤5%(No-load or pure resistive load) | ||||||
Test time | 0.0s~999s 0.0=continuous test | ||||||
DCW | Output voltage range | ———— | (0.00~5)kV | ———— | (0.00~5.00)kV | ||
Maximum output power | ———— | 50VA(5kV/10mA) | ———— | 100VA(5.00kV/20mA) | |||
Maximum rated current | ———— | 10mA | ———— | 20mA | |||
Current taps | ———— | 2mA,10mA | ———— | 2mA,20mA | |||
Ripple factor | ———— | ≤5% | ———— | ≤5% | |||
Test time | ———— | 0.0s~999s 0.0= Continuous test | ———— | 0.0s~999s 0.0=continuous test | |||
V | Range | (0.00~5.00KV) | |||||
accuracy | ±(5%+3 words) | ||||||
Resolution | 10V | ||||||
Display the value | Root mean square value | ||||||
A | measuring range | AC | 0.100mA~20.0mA | 0.100mA~100mA | 0.1mA~200mA | ||
DC | ———— | 0.1mA~10.0mA | ———— | 0.100mA~20.0mA | |||
Resolution | 2mAfile:1uA,20mA file:10uA,100mA(200mA) file:0.1mA | ||||||
measurement accuracy | ±(5%+3 words) | ||||||
Timer | range | 0.0s~999s | |||||
Minimum resolution | 0.1s | ||||||
Accuracy | ±(1% + 50ms) | ||||||
Interface of PLC | Optional | ||||||
Remote control interface | Yes | ||||||
Exterior dimension | 315*285*175mm | 440*380*180 | 430*375*190 | ||||
Weight | 8.76Kg | 9.10Kg | 13.72Kg | 18.2Kg | 24.6Kg |
2)Technical parameter of ZX2671A,ZX2671B,ZX2671C
Items | Model | ZX2671A | ZX2671B | ZX2671C | |||
ACW | Output voltage range | (0.00 ~10.00)kV | |||||
Maximum output power | 200VA(10.0kV/20mA) | 500VA(10.0kV/50mA) | 1000VA(10.0kV/100mA) | ||||
Maximum rated current | 20mA | 50mA | 100mA | ||||
Current taps | 2mA,20mA | 2mA,20mA,50mA | 2mA,20mA,100mA | ||||
Output waveform | Sine wave | ||||||
Output waveform distortion | ≤5%(No-load or pure resistive load) | ||||||
Test time | 0.0s~999s 0.0=continuous test | ||||||
DCW | Output voltage range | (0.00~10.0)kV | |||||
Maximum output power | 100VA(10.0KV/10mA) | 200VA(10.0KV/20mA) | |||||
Maximum rated current | 10mA | 20mA | |||||
Current taps | 2mA,10mA | 2mA,20mA | |||||
Ripple factor | ≤5 % | ||||||
Test time | 0.0s~999s 0.0=continuous test | ||||||
V | Range | (0.00~10.0KV) | |||||
accuracy | ±(5%+3 words) | ||||||
Resolution | 10V | ||||||
Display the value | Root mean square value | ||||||
A | measuring range | AC | 0.100mA~20.0mA | 0.100mA~50mA | 0.100mA~100mA | ||
DC | 0.100mA ~10.0mA | 0.100mA ~20.0mA | |||||
Resolution | 2mA stop:1uA, 20mA stop:10uA,50mA(100mA) stop:0.1mA | ||||||
measurement accuracy | ±(5%+3 words) | ||||||
Time meter | range | 0.0s~999s | |||||
Minimum resolution | 0.1s | ||||||
Accuracy | ±(1% + 50ms) | ||||||
PLC interface | Optional | ||||||
Remote control interface | Yes | ||||||
Exterior dimension | 380*305*195mm | 443*390*220mm | 440*380*180mm | ||||
Weight | 14.76Kg | 25Kg | 18.2Kg |
![]() |